Engineer Training Flash Cards
ABTH Only
GCOR Only
Random Question
Weekend Study

Any question, rule number, or answer reported as wrong will get looked at manually in a couple of days. Please write what is wrong with this flash card and what it should be which will speed up the correction process.
-Thank you!

What is wrong:

No Pending Requests Have Been Submited

Card has been updated: 1 time(s)
Front #29

ABTH 100.9A

There are two methods used to conduct a Brake Pipe Leakage Test. In both methods, you need to charge the brake system to within ____ of the regulating valve as indicated by a gauge or device at the rear of the train.


  1. 10 psi
  2. 20 psi
  3. 15 psi
  4. 90 psi
Back #29
Flag

ABTH 100.9A


Answer: 15 psi
Feedback:
Regulating valve settings: - Freight service = 90 psi - Passenger service = 105 psi - The pressure at rear of train must be within 15 psi of the pressures listed above. - The pressure at rear of the train must be determined by one of the following: A gauge verified to be accurate, an ETD, or a DP locomotive consist.